Installation Instructions TYPE P D GAS SERIES 3 Weil McLain Boiler GENERAL INSTRUCTIONS Locate the boiler as close as possible to the chimney taking care to provide ample clearance for access to the piping It is required that a clearance of 24 be allowed at sides where ser vicing will occur and 18 allowed at a side where passage is necessary to another side re quiring servicing or cleaning Minimum clearance on remaining sides should be no less than 6 See Page 3 for permissable minimum clearance for alcove installations NOTE Installations must conform with the re quirements of local utilities and those of other local authorities having jurisdiction CHIMNEY OR FLUE The masonry chimney or Type A flue to which the boiler is connected mu ...